Structured light scanning (SLS) and white light scanning (WLS) are non-contact, full-field 3D measurement technologies that capture the complete surface geometry of a physical object in a single scan. To understand how they work, first define two core terms:
White light scanning is a subset of structured light scanning that uses broadband white light (instead of laser or monochromatic light) for projection. For the purposes of manufacturing, the two terms are often used interchangeably, with WLS referring to the most common industrial implementation of SLS.
At their core, SLS/WLS measure two critical sets of data:
The value of SLS/WLS lies in its ability to bridge the gap between digital design (CAD) and physical production. For CNC manufacturing, this impacts three key areas: part function, assembly performance, and cost.
Many parts require precise geometric compliance to meet functional requirements. For example:
SLS/WLS captures the full surface of these parts, allowing engineers to identify deviations that would be missed by discrete point measurements.
For multi-part assemblies, even minor deviations in individual parts can compound to cause fit issues. For example:
SLS/WLS reduces manufacturing costs in two key ways:
Industrial SLS/WLS systems typically consist of three core components: a light projector, one or more cameras, and a computer for data processing. The measurement process follows four key steps:
Before scanning, the system is calibrated to establish the precise relationship between the projector, cameras, and a reference coordinate system. Calibration involves projecting a series of patterns onto a calibration target (a plate with known 3D features) and using the captured images to calculate the system’s intrinsic parameters (e.g., camera focal length, lens distortion) and extrinsic parameters (e.g., the relative position and orientation of the projector and cameras). Calibration is critical for ensuring measurement accuracy, and it must be repeated periodically to account for changes in the system (e.g., temperature fluctuations, mechanical drift).
The projector projects a sequence of structured light patterns onto the part’s surface. These patterns are designed to encode unique information into each point on the surface, allowing the system to identify and track individual points across multiple images. For example, a common pattern sequence involves projecting a series of vertical stripes of varying widths, followed by a series of horizontal stripes. The cameras capture images of the part as each pattern is projected.
For each point on the part’s surface, the system uses the distorted pattern information to calculate its 3D coordinates. This process, called triangulation, works by determining the angle at which light from the projector hits the point and the angle at which the reflected light is captured by the cameras. Using the known distance between the projector and cameras (the baseline), the system can calculate the 3D position of the point.
The raw 3D points are combined into a point cloud, which is then processed to remove noise and outliers. The point cloud can be aligned to a coordinate system (e.g., the part’s CAD model) and used to generate a 3D mesh (a surface representation of the part) for further analysis.
The accuracy of SLS/WLS systems varies widely depending on the system’s design, the size of the part being scanned, and the measurement conditions. Typical industrial systems have an accuracy range of 0.01mm to 0.1mm for parts up to 1m in size. For example, a high-precision SLS system used for inspecting small parts machined on the GA-DV750 (positioning accuracy 0.003mm) may have an accuracy of 0.01mm, while a system used for scanning large parts machined on the GA-GF4028 (positioning accuracy 0.02mm) may have an accuracy of 0.05mm.
It is important to note that SLS/WLS accuracy is often specified as the system’s maximum error, not the error across the entire part. For large parts, the error can vary across the surface, with higher error at the edges of the scan volume.
SLS/WLS measurements are affected by a variety of error sources, which can be grouped into four categories:
These errors are inherent to the SLS/WLS system and are influenced by its design and calibration:
These errors are caused by the properties of the part being scanned:
These errors are caused by the conditions in which the scan is performed:
These errors are caused by how the scan is performed:
SLS/WLS is a powerful measurement technology, but it has several important limitations that users must be aware of to avoid overconfidence in the results:
SLS/WLS is a line-of-sight technology, meaning it can only measure surfaces that are visible to the projector and cameras. It cannot measure internal features that are not accessible, such as the internal diameter of a deep hole or the internal structure of a closed assembly. For these features, other measurement technologies (e.g., CMMs with touch probes, bore gauges) are required.
While SLS/WLS can capture a large number of points quickly, its accuracy for individual points is typically lower than that of high-precision CMMs. For example, a high-precision CMM may have an accuracy of 0.001mm for discrete point measurements, while a high-precision SLS system may have an accuracy of 0.01mm. This means that for applications requiring extremely high accuracy for specific features (e.g., the position of a critical hole), SLS/WLS may not be sufficient.
The point cloud generated by SLS/WLS contains noise, which can be caused by surface texture, vibration, or other error sources. This noise can make it difficult to accurately measure small features, such as sharp edges or small holes. For example, a 0.1mm diameter hole may appear as a 0.15mm diameter hole in the point cloud due to noise.
SLS/WLS only measures the surface geometry of a part. It cannot measure material properties (e.g., hardness, tensile strength) or subsurface defects (e.g., cracks, porosity). For these measurements, other technologies (e.g., ultrasonic testing, X-ray inspection) are required.
A common misconception is that SLS/WLS captures the entire surface of a part. In reality, parts with complex geometries often require multiple scans, and even then, some areas may be occluded. Users must carefully inspect the point cloud to ensure that all critical features are captured before relying on the measurement results.
| Method | Typical Accuracy | Effort | Typical Use Case |
|---|---|---|---|
| Structured Light/White Light Scanning (SLS/WLS) | 0.01mm–0.1mm (part size dependent) | Low to medium: Fast scan (seconds to minutes), requires part preparation (coating, fixturing) and post-processing | Full-part inspection, assembly fit analysis, reverse engineering, CAD comparison for complex geometries |
| High-Precision CMM (Touch Probe) | 0.001mm–0.01mm | High: Slow measurement (hours for complex parts), requires skilled operator | Discrete point measurement for critical features, high-accuracy dimensional inspection |
| Laser Scanning | 0.02mm–0.2mm | Medium: Fast scan, can be used for large parts, less sensitive to surface reflectivity | Large part inspection, reverse engineering of large objects |
To ensure accurate and reliable SLS/WLS measurements, follow this checklist:
Define measurement requirements upfront:
Select the appropriate SLS/WLS system:
Prepare the part and environment:
Calibrate the system:
Plan the scan strategy:
Process and validate the data:
Q: Can SLS/WLS be used to inspect parts machined on high-precision CNC centers like the GA-UHD500? A: Yes, but with caveats. The GA-UHD500 has a positioning accuracy of 0.006mm and repeatability of 0.004mm. High-precision SLS/WLS systems can achieve accuracy of 0.01mm, which is sufficient for many applications. However, for critical features requiring accuracy better than 0.01mm, a high-precision CMM is still recommended.
Q: How does SLS/WLS compare to CMM for inspecting large parts machined on gantry centers like the GA-GF4028? A: SLS/WLS is often faster and more cost-effective for large parts. A CMM inspection of a large part can take hours, while SLS/WLS can scan the same part in minutes. SLS/WLS also provides full-field data, allowing engineers to identify deviations across the entire part, not just at discrete points. However, CMMs still offer higher accuracy for individual point measurements.
Q: Can SLS/WLS be used for reverse engineering parts? A: Yes, SLS/WLS is widely used for reverse engineering. The point cloud generated by SLS/WLS can be used to create a 3D CAD model of the part, which can then be used for manufacturing, repair, or analysis.
Q: What is the maximum part size that can be scanned with SLS/WLS? A: The maximum part size depends on the system’s scan volume. Small systems can scan parts up to 1m in size, while large systems can scan parts up to 10m or more. For very large parts, multiple scans are often taken and then aligned to form a complete point cloud.
Q: How often should an SLS/WLS system be recalibrated? A: Recalibration frequency depends on the system’s usage and environmental conditions. As a general rule, systems should be recalibrated before each scan session, or if the temperature changes by more than 1°C, or if the system is moved or damaged. It is also recommended to perform a full recalibration at least once a month for systems used in production environments.
Send us your part, batch size and target port. We reply with a configuration, a binding lead window and a total-cost comparison.
Request a quote →